| ATM-960 Series Modems - 6000 Meter Depth Rated
Hard-coat anodized aluminum housings
|
 |
| ATM-964 Remote Transducer, Integral Battery |
| Depth |
6000 m (19,680 ft) |
 |
| Size |
Transducer: 5.5 in (14.0 cm) diameter x 4.0 in (10.1 cm) height
Modem: 5.0 in (12.7 cm) diameter x 29.0 in (73.6 cm) length |
| Weight |
41 lbs (18.6 kg) Dry
20 lbs (9.1 kg) Wet |
| Power |
588 W•Hr internal batteries (can also be powered by external source)
|
| Frequencies |
Low frequency (LF) 9-14 kHz
Mid frequency (MF) 16-21 kHz
Band C frequency 22-27 kHz |
| Transducer |
Omni directional (180° beam)
Directional (60° beam) |
| Connection |
MCBH16M connector, wired for dual serial port option. 16-pin dual port serial programming cable included
|
|
|
|
 |
| ATM-965 Integral Transducer, Integral Battery |
| Depth |
6000 m (19,680 ft) |
 |
| Size |
5.0 in (12.7 cm) diameter x 29.0 in (73.6 cm) length |
| Weight |
36 lbs (16.3 kg) Dry
17 lbs (7.7 kg) Wet |
| Power |
588 W•Hr internal batteries (can also be powered by external source) |
| Frequencies |
Low frequency (LF) 9-14 kHz
Mid frequency (MF) 16-21 kHz
Band C frequency 22-27 kHz |
| Transducer |
Omni directional (180° beam)
Directional (60° beam) |
| Connection |
MCBH16M connector, wired for dual serial port option. 16-pin dual port serial programming cable included |
|
|
 |
| ATM-966 Integral Transducer, No Integral Battery |
| Depth |
6000 m (19,680 ft) |
 |
| Size |
5.0 in (12.7 cm) diameter x 14.5 in (36.8 cm) length |
| Weight |
15 lbs (6.8 kg) Dry, 5 lbs (2.3 kg) Wet |
| Power |
No internal batteries. 12-36VDC external power required |
| Frequencies |
Low frequency (LF) 9-14 kHz
Mid frequency (MF) 16-21 kHz
Band C frequency 22-27 kHz |
| Transducer |
Omni directional (180° beam)
Directional (60° beam) |
| Connection |
MCBH16M connector, wired for dual serial port option. 16-pin dual port serial programming cable included |
|
|
General Specifications
| Baud Rate |
140-15,360 bps |
| Bit Error Rate |
Better than 10-7 with high SNR |
| Data Storage |
6144 Kbyte Data logger standard |
| Processing |
Data redundancy, 1/2 rate convolutional coding mulitpath guard period selection MFSK and PSK modulation schemes |
| Distances/Range |
2-6 km common, greater distances possible, 20+ km available using repeater functionality |
| Data Connection |
RS-232, RS-422 or RS-485 supported |
|
.png) |
Related Equipment